DeWalt DC841 Instruções de Operação Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 22
23
Instructions for Changing the Motor Voltage
1) Disconnect and lockout power– Electrical shock could occur if this is not done.
2) Reconnect motor and transformer leads as shown in the chart above to match
your required voltage.
3) Reset the dial for the proper amperage setting shown in the chart above. If your
overload block does not have the proper settings, the block will have to be replaced
with one appropriate for your voltage.
4) Recheck all connections and replace lids on the motor box and magnetic starter
enclosure before restoring power.
Changing the Motor Voltage
WARNING—DISCONNECT AND LOCKOUT POWER BEFORE SERVICING
If your machine requires a different voltage, follow the instructions below. The motor will
need to be rewired according to the diagrams below. The thermal overloads must be reset
or replaced with the proper pieces to maintain thermal motor protection.