3.5 CONTROL MODULE
Figure 3: Control Module
POWER ON LIGHT: Illuminates when battery voltage is applied to control module.
RED X-RAY PULSING LIGHT: Blinks after time delay button or remote cable button is pressed to warn
that the XRS-4 is going to pulse. The light stays on continuously while the XRS-4 is pulsing. This is a
failsafe warning light. If the light does not work the X-ray unit will not pulse.
LIQUID CRYSTAL DISPLAY (LCD): Two digit LCD displays selected pulse, time before unit pulses,
software version, and total number of pulses on the unit.
RANGE SWITCH: Used to alternate LCD between tens digit and ones digit.
UNITS SWITCH: Used to change the value of the tens digit or units digit from 0 to 9. The UNITS
SWITCH is also used with the EMERGENCY STOP SWITCH to alter the default pulse setting.
DELAY SWITCH: Initiates delay mode.
EMERGENCY STOP SWITCH: Stops the unit before it begins pulsing or stops the unit in the middle of a
pulse train. This switch can also be pressed with the UNITS SWITCH to alter the default pulse setting
when the XRS-4 is first powered up.
CABLE CONNECTOR: Lemo connector located on the back of the control module beneath the battery
receives the remote cable or imaging system cable. See Rear View Diagram on page 5 for details.
BACK PLATE: Covers the Oscillator board and contains battery terminal connectors.
UNITS SWITCH
DELAY SWITCH
RANGE SWITCH
LCD
X-RAY PULSING LIGHT
KEY
EMERGENCY STOP \
PULSE DEFAULT
POWER ON LIGHT
CABLE CONNECTOR
BACK PLATE